// THE QUESTION BANK
A little focus.
A better attempt.
Find your topic. Work through a few questions. Open the official answer when one is available.
Loading your next set of questions…
// THE QUESTION BANK
Find your topic. Work through a few questions. Open the official answer when one is available.
Loading your next set of questions…
// THE QUESTION BANK
Find your topic. Work through a few questions. Open the official answer when one is available.
YOUR SELECTION
Showing 1–12 · 1 paper
Question 1
From Anna University — Power System Analysis (EE8501), April/May 2023
Define bus impedance matrix.
Write your answer in full; there are no options to pick from.
No verified answer is available for this question.
Question from the source paper. Published documents are listed by the exam body at its document index.
Question 2
From Anna University — Power System Analysis (EE8501), April/May 2023
List the advantages of per unit computations.
Write your answer in full; there are no options to pick from.
No verified answer is available for this question.
Question from the source paper. Published documents are listed by the exam body at its document index.
Question 3
From Anna University — Power System Analysis (EE8501), April/May 2023
What is P-Q bus in power flow analysis?
Write your answer in full; there are no options to pick from.
No verified answer is available for this question.
Question from the source paper. Published documents are listed by the exam body at its document index.
Question 4
From Anna University — Power System Analysis (EE8501), April/May 2023
What do you mean by flat voltage start?
Write your answer in full; there are no options to pick from.
No verified answer is available for this question.
Question from the source paper. Published documents are listed by the exam body at its document index.
Question 5
From Anna University — Power System Analysis (EE8501), April/May 2023
What is the need for short circuit analysis?
Write your answer in full; there are no options to pick from.
No verified answer is available for this question.
Question from the source paper. Published documents are listed by the exam body at its document index.
Question 6
From Anna University — Power System Analysis (EE8501), April/May 2023
Define bolted fault.
Write your answer in full; there are no options to pick from.
No verified answer is available for this question.
Question from the source paper. Published documents are listed by the exam body at its document index.
Question 7
From Anna University — Power System Analysis (EE8501), April/May 2023
What are symmetrical components?
Write your answer in full; there are no options to pick from.
No verified answer is available for this question.
Question from the source paper. Published documents are listed by the exam body at its document index.
Question 8
From Anna University — Power System Analysis (EE8501), April/May 2023
List the various types of unsymmetrical faults.
Write your answer in full; there are no options to pick from.
No verified answer is available for this question.
Question from the source paper. Published documents are listed by the exam body at its document index.
Question 9
From Anna University — Power System Analysis (EE8501), April/May 2023
Define power angle.
Write your answer in full; there are no options to pick from.
No verified answer is available for this question.
Question from the source paper. Published documents are listed by the exam body at its document index.
Question 10
From Anna University — Power System Analysis (EE8501), April/May 2023
State equal area criterion.
Write your answer in full; there are no options to pick from.
No verified answer is available for this question.
Question from the source paper. Published documents are listed by the exam body at its document index.
Question 11
From Anna University — Power System Analysis (EE8501), April/May 2023
(a) Obtain PU impedance diagram of the power system of figure. Choose base quantities as 15 MVA and 33 KV. Generator: 30 MVA, 10.5KV, X"= 1.6 ohms. Transformers T₁ and T₂: 15 MVA, 33/11 KV, X = 15 ohms referred to HV. Transmission line: 20 ohms / phase. Load: 40 MW, 6.6 KV, 0.85 lagging p.f. (OR) (b) Form Y-bus of the system shown in Fig. 11(b) using singular transformation method. The impedance data is given in the table. Take bus 1 as reference node. Element No. - Self - Bus Code - Self - Impedance (p.u.) - Mutual - Bus Code - Mutual - Impedance (p.u.) 1 - 1-2 - 0.5 - - - 2 - 1-3 - 0.6 - 1-2 - 0.1 3 - 3-4 - 0.4 - - - 4 - 2-4 - 0.3 - - -


Write your answer in full; there are no options to pick from.
No verified answer is available for this question.
Question from the source paper. Published documents are listed by the exam body at its document index.
Question 12
From Anna University — Power System Analysis (EE8501), April/May 2023
(a) Prepare the load flow algorithm using gauss seidal method with the flowchart and discuss the advantages of the method. (OR) (b) A three bus power system is shown in Fig. 12(b) and its data's are given in the table. Bus No. - Type - Generation - P_G - Q_G - Load - P_L - Q_L - Bus Voltage - V - δ 1 - Stack - - - - - - - - 1.02 - 0 2 - PQ - 0.25 - 0.15 - 0.5 - 0.25 - - - - 3 - PQ - 0 - 0 - 0.6 - 0.3 - - - - Determine the voltages at buses 2 and 3 after 1st iteration using gauss-seidal method. Take the acceleration factor α = 1.6.

Write your answer in full; there are no options to pick from.
No verified answer is available for this question.
Question from the source paper. Published documents are listed by the exam body at its document index.
Questions the exam body withdrew, and questions that need unavailable source figures, are stored with their papers and withheld here. Each served question links to its source paper.
This is self-study practice. It does not issue assessment results, certificates or profile proof. Attempts on this page reset when you leave it.