Anna University — Power System Analysis (EE8501), April/May 2023
Power System Analysis · EE8501 · R2017 · B.E. Electrical and Electronics Engineering · Semester 5
Files open in a new tab. Use your browser's download or save option to keep a copy.
Work through the questions
16 questions
No verified answers are available for this paper.
Define bus impedance matrix.
No verified answer or solution is available for this question.
List the advantages of per unit computations.
No verified answer or solution is available for this question.
What is P-Q bus in power flow analysis?
No verified answer or solution is available for this question.
What do you mean by flat voltage start?
No verified answer or solution is available for this question.
What is the need for short circuit analysis?
No verified answer or solution is available for this question.
Define bolted fault.
No verified answer or solution is available for this question.
What are symmetrical components?
No verified answer or solution is available for this question.
List the various types of unsymmetrical faults.
No verified answer or solution is available for this question.
Define power angle.
No verified answer or solution is available for this question.
State equal area criterion.
No verified answer or solution is available for this question.
(a) Obtain PU impedance diagram of the power system of figure. Choose base quantities as 15 MVA and 33 KV. Generator: 30 MVA, 10.5KV, X"= 1.6 ohms. Transformers T₁ and T₂: 15 MVA, 33/11 KV, X = 15 ohms referred to HV. Transmission line: 20 ohms / phase. Load: 40 MW, 6.6 KV, 0.85 lagging p.f. (OR) (b) Form Y-bus of the system shown in Fig. 11(b) using singular transformation method. The impedance data is given in the table. Take bus 1 as reference node. Element No. - Self - Bus Code - Self - Impedance (p.u.) - Mutual - Bus Code - Mutual - Impedance (p.u.) 1 - 1-2 - 0.5 - - - 2 - 1-3 - 0.6 - 1-2 - 0.1 3 - 3-4 - 0.4 - - - 4 - 2-4 - 0.3 - - -

Fig. 11 (a) - single line diagram with generator G1, T1, LINE, T2 and LOAD 
Fig. 11(b) - four-bus network with buses 1, 2, 3, 4 and a j0.1 branch No verified answer or solution is available for this question.
(a) Prepare the load flow algorithm using gauss seidal method with the flowchart and discuss the advantages of the method. (OR) (b) A three bus power system is shown in Fig. 12(b) and its data's are given in the table. Bus No. - Type - Generation - P_G - Q_G - Load - P_L - Q_L - Bus Voltage - V - δ 1 - Stack - - - - - - - - 1.02 - 0 2 - PQ - 0.25 - 0.15 - 0.5 - 0.25 - - - - 3 - PQ - 0 - 0 - 0.6 - 0.3 - - - - Determine the voltages at buses 2 and 3 after 1st iteration using gauss-seidal method. Take the acceleration factor α = 1.6.

Fig. 12(b) - three-bus power system with line reactances -j3, -j4 and -j5 No verified answer or solution is available for this question.
(a) Explain the step by step procedure to find the fault current of three phase symmetrical fault current by using Thevenin's theorem. (OR) (b) For the radial network shown in Fig. 13 (b), a three phase fault occurs at point F. Examine the fault current.

Fig. 13 (b) - radial network with G1, G2, T1, OH LINE, T2, FEEDER and fault at F No verified answer or solution is available for this question.
(a) A single line to ground fault occurs at bus 4 of the system shown in Fig. 14(a). (i) Draw the equivalent networks (ii) Compute fault current. G₁, G₂: 100 MVA, 20 kV, X′=X″ = 20%, X₀ = 4%, Xₙ = 5% T₁, T₂: 100 MVA, 20/345 kV, X_leak = 8% on 100 MVA Tr. Line: X′ = X″ = 15%, X = 50% on a base of 100 MVA, 20kV. (OR) (b) Derive the expression for fault current for a double line to ground fault in an unloaded generator in terms of symmetrical components.

Fig. 14(a) - network with G1, G2, buses 1 to 4, T1, T2 and neutral reactances Xn No verified answer or solution is available for this question.
(a) Describe the equal area criterion for transient stability analysis of a system. (OR) (b) Given the system of Fig. 15(b) shown below where a three phase fault is applied at a point P as shown. Examine the critical clearing angle for clearing the fault with simultaneous opening of the breakers 1 and 2. The reactance values of various components are indicated in the diagram. The generator is delivering 1.0 p.u. power at the instant preceding the fault. The fault occurs at point P.

Fig. 15(b) - single machine infinite bus diagram with breakers 1 and 2, fault point P and M = 1 angle 0 degrees No verified answer or solution is available for this question.
(a) A 3-phase 6 MVA, 6.6 KV alternator with a reactance of 12% is connected to a feeder of series impedance (0.10+j0.5) ohm/phase/Km through a step up transformer. The transformer is rated at 3 MVA, 6.6 KV/33KV and has a reactance of 7%. Determine the fault current supplied by the generator operating under no load with a voltage of 6.9 KV when a three phase symmetrical fault occurs at a point 16 Km along the feeder. (OR) (b) A 50 Hz, 500 MVA, 400 KV generator (with transformer) is connected to a 400 KV infinite bus bar through an interconnector. The generator has H = 2.5 MJ/MVA. Voltage behind transient reactance of 450 KV and is loaded 460 MW. The transfer reactances between generator and bus bar under various conditions are: Prefault 0.5 p.u., During Fault 1.0 p.u., Post fault 0.75 p.u. Calculate the swing curve using intervals of 0.05 sec and assuming that the fault is cleared at 0.15 sec.
No verified answer or solution is available for this question.